Cold Aisle Containment

Cold Aisle Containment

INCREASE COOLING EFFICIENCY SOLUTIONS

COLDWEAR

About the Containment

          In the past, companies used a lot of energy to maintain a stable temperature inside the data center , Thus, the amount of energy used in the cooling process of the Data Center room is considered one of the wasteful expenses. Therefore, installing Cold Aisle Containment to keep the air conditioning system in the Data Center working efficiently. Therefore, it is one of the choices that have a very good result.

          The main function of containment is Prevents the mixing of hot and cold air. The cold air will spread through the raised floor until the front of the rack is separated from the hot air zone. Make IT equipment cooling effectively. due to The air conditioning system in the computer center can work. effectively because it is a separation between cold and hot air The cool air is only inside the containment, while the hot air is sent to the Computer Room Air Conditioning (CRAC)

          After Installing Containment multiple data centers Cooling power consumption is reported to be reduced by 5-15%, resulting in a dramatic decrease in costs. Cold Aisle Containment (CAC) has become today’s data center best practice.

       

Cold Aisle Containment
in the Ordinary world
BE EXTRA-ORDINARY

     If building a Data Center room, the important factor is the huge cost.

     One more thing that is equally important. is maintenance or repair in the event that IT equipment is damaged whether caused by the environment in the room or from the operator to prevent damage that will occur and nurture IT equipment to work at full efficiency for a long time

     Installing a system to prevent the mixing of hot air and cold air, such as Cold Aisle Containment, is another option. that many organizations choose to use

      Coldwear innovations will make it easier for you to make decisions. Whether it is an automatic roof that will open when receiving an alarm from the Fire Suppression system, the unique feature of this automatic roof is The panels will not fall down after being opened. This prevents damage to IT equipment or the operator It is also easy to maintenance. Or an internal fault detection system within the containment, as well as an notification system that send to the operetor.

Automatic roof Opened
Automatic Roof Closed
The Ultimate in Advanced
FEATURES

Automatic roof

automatic ceiling It can be opened automatically when receiving an emergency signal (Fire Alarm) from the Fire Suppression System and can also be controlled manually by unlocking each door.

Notification System

Connect to BMS, EMS and DCIM systems via Protocal Modbus. Send notifications of various status via Application Line to users quickly (J1000 Series Option).

Durable, HighQuality Materials

Made of lightweight aluminum material. but durable You can choose the color from the factory according to your specific needs.

Cold Aisle Containment Part

Prevent Damage

Ceiling Panels open 90 degrees, each panel can be removed with bare hands. without special tools When there is an emergency, it will not falldown to cause damage.

Modular Design

Can be used with rack cabinets, width 60 cm., 80 cm. and other sizes. Can be assembled with racks of other manufacturers, even if they are not the same brand.

Non-flammable

Ceiling Panels are made of polycarbonate. It is non-flammable, translucent and has a light transmission value of 80%.

Cold Aisle Containment

Automatic Roof

   In addition being able to prevent the mixing of hot and cold air. The Roof also has many features whether

  • Automatic open When receiving the alarm signal from fire suppression system
  • When opened, it will not fall down causing damage
  • Good light Transmission, Light weight, flame resistance
  • Strong and durable magnetic lock
  • It is designed to be easy to install Expand and easy maintenance
Automatic roof
Models of Ceiling Panels

CRA-1306

  • Dimension 600 x 1300 x 16 mm 
  • Dual swing 568 x 580 mm 
  • Magnetic Lock 60 kg 12Vdc
  • Working temperature 5-45 Celsius
  • Compatibility with Containment Roof Automatic Controller Unit

CRA-1308

  • Dimension 800 x 1300 x 16 mm 
  • Dual swing 768 x 580 mm 
  • Magnetic Lock 60 kg 12Vdc
  • Working temperature 5-45 Celsius
  • Compatibility with Containment Roof Automatic Controller Unit

CRA-1806

  • Dimension 600 x 1800 x 16 mm 
  • Dual swing 568 x 580 mm 
  • Magnetic Lock 60 kg 12Vdc
  • Working temperature 5-45 Celsius
  • Compatibility with Containment Roof Automatic Controller Unit

DRIVEN BY INNOVATION

Noticfication system

            For the Data Center to function as efficiently and stably as possible, all systems must be ready. In use, it must be known as soon as a malfunction occurs.

          Our containment has a system of measuring equipment for various abnormalities Which will connect to 3th Party devices like Connect Plus 1000 that will receive notifications of malfunctions from detected devices. The notification will be sent as SMS / Email / Line Notify directly to the administrator.

Notification for data center
CRA-CU

Containment Roof Automatic

Controller Unit

Containment roof automatic Controller Unit is a Containment ceiling panel control. It can be used with the Containment ceiling model CRA-1306, Cra-1308 and CRA-1808. The controller will unlock the mechanism that locks the ceiling panel of the Containment when there is an alarm signal. fire from fire suppression system Make the ceiling panel of the container unlock automatically. To enable the fire suppression system to suppress the fire within the container, users can also manually control the unlocking of each container’s ceiling panels.

Manual Control

With a Manual mode can Operate some Containment ceiling

Automatic Control

Automatic Operate with Fire alarm active signal form Fire suppression system

Key Switch Lock

For protection operate in manual mode from front panel

Controller unit for containment

LED Indicator

LED Indicator status of the Containment roof automatic

Compatibility

Compatinility Containment Roof Automatic model CRA-1306, CRA-1308, CRA-1806

Connect to 3th Party

Connect to 3th party devices such as ConnectPlus J1000 for monitor and notice or external systems.

Partner in Thailand is Totalmaker

About Us

Location

30 Soi Nimitmai30 Samwatawanaok Klongsamwa Bangkok 10510.

Contact Us

Phone : +66 (0)2 130 7896